Chapter 3 BIOS Setup

Chapter 3

PC Health Status

This section displays the hardware health monitor.

CPU Smart Fan Control

When this feature is set to Automatic, the CPU’s fan speed will rotate according to the

CPU’s temperature. The higher the temperature, the faster the speed of rotation.

Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.

Version 2.15.1236. Copyright (C) 2012 American Megatrends, Inc.

PC Health Status

Smart Fan Function

Case Open

CPU

Temperature

System

Temperature

CPU Fan Speed
System Fan Speed
VCORE
+5V
+12V
+1.5V
+3.3V
3VSB
VBAT

Advanced

[Disabled]

: +32.0 C
: +36.5 C
: 1274 RPM
: N/A
: +1.728 V
: +5.077 V
: +11.968 V
: +1.520 V
: +3.328 V
: +3.376 V
: +3.040 V

Smart Fan Function Setting

Smart Fan Function

Aptio Setup Utility - Copyright (C) 2012 American Megatrends, Inc.

Version 2.15.1236. Copyright (C) 2012 American Megatrends, Inc.

Smart Fan Function

CPU Smart Fan Control

Boundary 4
Boundary 3
Boundary 2
Boundary 1
Speed Count 5
Speed Count 4
Speed Count 3
Speed Count 2
Speed Count 1

System Smart Fan Control
Boundary 4
Boundary 3
Boundary 2
Boundary 1
Speed Count 5
Speed Count 4
Speed Count 3
Speed Count 2
Speed Count 1

Advanced

[Enabled]

60
50
40
30
100
75
50
40
30

[Enabled]
60
50
40
30
100
75
50
40
30

Enable CPU Smart Fan

System Smart Fan Control

When this feature is set to Automatic, the System’s fan speed will rotate according to

the System’s temperature. The higher the temperature, the faster the speed of rotation.

Boundary 1 to Boundary 4

The range is 0-127.

Speed Count 1 to Speed Count 5

The range is 1-100%.

Case Open

Sets this field to Enabled to allow the system to alert you of a chassis intrusion event.



Select Screen



Select Item

Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous

Values

F3: Optimized

Defaults

F4: Save & Reset
ESC: Exit



Select Screen



Select Item

Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous

Values

F3: Optimized

Defaults

F4: Save & Reset
ESC: Exit

Advertising