INSTALLER FINAL CHECKLIST:

GRILL BURNER FLAME HEIGHT:

To access the grill burner air shutters first remove the valve panel by removing it the same way as
described on page 12, section “Before Testing”. With a screw driver, loosen the lock-screw on the face
of the air shutter. Light the burner and adjust according to the directions below.

❏ Specified 12” clearances

maintained to combustibles.

❏ Verified proper enclosure

ventilation.

❏ Nylon straps removed from

burners.

❏ All internal packaging

removed.

❏ Knobs turn freely, bezels

centered.

❏ Each burner lights satisfac-

torily, individually or with
adjacent burner lit.

❏ Air shutters adjusted.
❏ Adjustable low setting satis-

factory.

❏ Drip pan in place properly

and sliding freely.

❏ Pressure regulator

connected and set for 4.0"
W.C. Natural, 11.2" W.C. LP
gas.

❏ Manual shut-off valve

installed and accessible.

❏ Unit tested and free of

leaks.

❏ User informed of gas supply

shut-off valve location.

❏ All radiants are assembled

(see page 15) and put in
place.

PLEASE LEAVE THESE
INSTRUCTIONS WITH THE
USER.

USER, PLEASE RETAIN
THESE INSTRUCTIONS
FOR FUTURE REFERENCE.

1-1/2"

3/8"

FIG. 07 Burner Flame Height

Sealed Burner

INSTALLER CHECKLIST/BURNER ADJUSTMENTS

FIG.09