Installing, Caution, Warning – Desa FLAME-MAX UNVENTED (VENT-FREE) PROPANE/LPGAS LOG HEATER User Manual

Page 18

Advertising
background image

18

103310

Tee Joint

Pipe

Nipple

Cap

3" Minimum

Sediment

Trap

Gas
Regulator

From

External Regulator

(11" W.C.** to

14" W.C.

Pressure)

A.G.A. Design-Certified
Manual Shutoff Valve
With 1/8" NPT Tap*

Approved Flexible
Gas Hose (if allowed
by local codes)

WARNING ICON

G 001

CAUTION

Avoid damage to regulator. Hold gas regulator with wrench when
connecting it to gas piping and/or fittings.

Figure 14 - Gas Connection

* Purchase the optional A.G.A. design-certified manual shutoff valve from your
dealer. See Accessories, page 34.
** Minimum inlet pressure for purpose of input adjustment.

INSTALLING

Continued

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG

1. Disconnect heater and its individual manual shutoff valve from gas supply

piping system. Pressures in excess of 1/2 psig will damage heater regulator.

2. Cap off open end of gas pipe where manual shutoff valve was connected.

WARNING ICON

G 001

WARNING

Never use an open flame to check for a leak. Apply a mixture of
liquid soap and water to all joints. Bubbles forming show a leak.
Correct all leaks at once.

WARNING ICON

G 001

WARNING

Test all gas piping and connections for leaks after installing or
servicing. Correct all leaks at once.

WARNING ICON

G 001

CAUTION

Make sure external regulator has been installed between propane
supply and heater. See guidelines under

Connecting to Gas Sup-

ply, page 16.

CHECKING GAS CONNECTIONS

Advertising