D// Load Connections:
The pack will dim any load from 1 watt through 1kW per channel.
This includes conventional incandescent and quartz incandescent
loads. Fluorescent loads can be controlled by the pack with no
damage to the dimmer, but the nature of these loads requires
specialized circuitry to get full range dimming. Consult the factory
if you need to dim such loads.

Merely plug the load or an extension cord to the load into the
outlet which corresponds to the circuit you wish to use. Always use
grounded cords. Loads may be single fixtures or combinations of
lights not exceeding 1kW per channel.
Each output channel is protected by a 10amp circuit breaker. If the
circuit breaker trips, it is due to an overload or short in the
output load.

E// Control Connections:
he pack accepts both DMX-512 and analog 0 to +10VDC control
signals (as a factory option). DMX-512 control signals are input
through the male five pin XLR connector on the case of the unit.
The connector is wired as shown in diagram XLR-1. Pins 4 and 5 are
not used but are passed on through other equipment. The dimmer
packs are wired in series along the control cable. Use one of the
specialty interface boxes for this purpose.

:Installation

A// Mechanical Installation:
For pipe mount use, a C-clamp and safety cable may be added
to the mounting bracket. It may be top or bottom hung by reversing
the yoke. For portable use, set the Dimmermaster “Shoebox” on a
smooth cool surface, preferably in an area that remains fairly cool.
Maximum air temperature must not exceed 50 degrees Centigrade
(122°F). Make certain that the vent holes all have at least 6 inches of
free air around them. Do not block any vent holes. It is essential
that this unit have adequate cooling for safe, reliable performance.

B// Electrical Installation:
The pack consists of four 1kW dimming channels. It requires a source
of 120 volts AC 50/60Hz at 20 amperes for full-power operation.
The actual amount of power consumed is determined by the total
wattage of the connected loads used; the dimmer itself consumes
negligible power. It is recommended that no other equipment be
connected to the circuit which is used for the pack, including that
on other outlets on same fuse or circuit breaker. If the building
circuit breaker trips, it may be necessary t reduce one of the loads.
Power input to the pack is via a flush-mount male connector either
motor base u-ground inlet (DM-406) for regular extension cords,
20A 125v twist lock NEMA L520 (DM-408), or a 30A 125V twist lock
NEMA L530 (DM-410) which is mounted on the back panel. Always use
3-wire, grounded cables. 12AWG or larger cable is recommended.

When power is connected, the status LED with light up in red
(60Hz line), yellow (50Hz line), and turn green when a DMX signal is
present.Grounding

C// The term “grounding” refers to a separate wire, usually with
green insulation, which is connected from the equipment case to earth
ground. This is not the same as the neutral, or “common” and must
not be confused with it; the neutral is a separate, load-carrying
conductor when the pack is connected to the power source by a
flexible cable, this ground connection is made through a third wire
in the cable and t ground prong on the plug. For maximum safety,
and to comply with electrical codes, this connection must be made.
Do not use an adapter (or “cheater”) plug.