Installation – Desa CGCFTP EN User Manual

Page 13

Advertising
background image

www.desatech.com

111044-01J

13

INSTALLATION

Continued

Remove
Screw

Valve
Cover
Shield

Shoulder Screw

Figure 13 - Removing Valve Cover Shield

Branch
Support

Snap Bushings

Bottom Louver
Assembly

Installing blower Assembly
(Models CGCFTP and CGCFTN)

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring errors

can cause improper and danger-

ous operation.

CAUTION: Verify proper op-

eration after servicing.

Note:

If you are using a mantel with your heater,

use the following instructions. If your heater is

built-in, see For Built-In Installation on page 14.

1. Install snap bushings found in hardware kit

into both holes in rear of valve cover shield.

2. Make sure the wire harness is firmly connected to

the terminals on the blower bracket assembly.

3. Note the wire locations on back of AUTO/

OFF/ON switch. The terminals on back of

switch are numbered 1, 2 and 3. Carefully

remove red wire from terminal 1 and blue

wire from terminal 3. Black wire can remain

on middle terminal 2 (see Figure 14).

4. Carefully disconnect green and white wires at

their insulated connectors.

5. In top of the heater cabinet, locate the four

mounting holes on the outer casing. Align

these four holes with those on the blower

bracket assembly. Attach blower bracket as-

sembly to the outer casing with 4 #10 screws

provided (see Figure 14).

6. Route the wire harness through the hole in

left side of baffle. Pull wire harness through

lower opening above where the valve shield

was removed. (see Figure 14).

7. Insert the 4 wire harness into one of the round

holes in the rear of the valve cover shield and

through the rectangular hole in the front of

shield (see Figure 14).

8. Reconnect red wire to switch position 3.

Reconnect blue wire to switch position 1.

Reconnect green and white wires.

9. Install the switch plate on the valve cover shield

with 2 #10 screws provided (see Figure 15).

Reinstall the valve cover shield. Route power

cord out of the cabinet by inserting it through the

bushing on the outer casing (see Figure 14). Plug

fan kit into 120-Volt grounded power supply and

test operation. Note: When switch is in the AUTO

position, the fan will start after the heater has run

for a few moments. The fan will continue to run for

several moments after the heater has been turned

off. When switch is in the ON position, the fan

will run until turned to OFF. Reinstall upper louver

assembly and hood if previously removed, (see

Figure 12, page 12). Close lower louver door.

Figure 14 - Installing Blower Bracket

Assembly

Wire Harness

Blower Bracket
Assembly

Screw

Power
Cord

Valve Cover Shield

Box
Cover

Wire
Harness

Switch
Plate

Switch

Baffle

Wiring Routing
Hole in Baffle

Blue

Red

Figure 15 - Installing Switch Plate to

Valve Cover Shield

Switch Plate

Screw

Valve
Cover
Shield

Advertising