Operating fireplace – Desa CGCFTP EN User Manual

Page 19

Advertising
background image

www.desatech.com

111044-01J

1

OPERATING FIREPLACE

Continued

6. With control knob pressed in, push down

and release ignitor button. This will light

pilot. The pilot is attached to the front of

burner. If needed, keep pressing ignitor

button until pilot lights.

Note: If pilot does not stay lit, refer to

Troubleshooting, page 22. Also contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

Note: If pilot goes out, repeat steps 3

through 7. This fireplace has a safety in-

terlock system. Wait one (1) minute before

lighting pilot again.

8. Turn control knob counterclockwise

to desired heating level. The main burner

should light. Set control knob to any heat

level between HI and LO.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Thermocouple

Pilot Burner

Figure 26 - Pilot

Ignitor
Electrode

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Fireplace

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off burner Only (pilot stays lit)

Turn control knob clockwise

to the PI-

LOT position.

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on this fireplace

differs from standard thermostats. Standard

thermostats simply turn on and off the burner.

The thermostat used on this fireplace senses the

room temperature. The thermostat adjusts the

amount of gas flow to the burner. This increases

or decreases the burner flame height. At times

the heater will cycle back on when room tem-

perature drops below the set temperature.

The control knob can be set to any heat level

between HI and LO.
Note:

The thermostat sensing bulb measures

the temperature of air near the fireplace

cabinet. This may not always agree with

room temperature (depending on housing

construction, installation location, room size,

open air temperatures, etc.). Frequent use of

your fireplace will let you determine your own

comfort levels.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions, page 18.

2. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

3. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Now follow step 8 under

Lighting Instructions, column 1.