Installation – Desa CGCFTP EN User Manual

Page 14

Advertising
background image

www.desatech.com

111044-01J

14

INSTALLATION

Continued

For Built-In Installation

WARNING: A licensed elec-

trician must connect the wiring

harness to electrical supply

following all local codes. Electri-

cian must provide a clamp on the

box cover to secure the wiring.

Wiring should be routed through

the bushing in the hole on the

outer casing of heater.

Follow instructions in Removing Valve Cover

Shield, page 12, then

1. Install a snap bushing found in hardware kit

into one of the holes found on rear of valve

cover shield. The other hole is for a strain

relief clamp (not supplied) to secure incoming

electrical supply.

2. Follow steps 2 through 6 in Installing Blower

Assembly, page 12. Also remove black wire

from middle switch terminal 2.

3. Remove black plastic strain relief and power

cord from switch plate. The power cord supplied

will not be used in built-in installations. Pop in

the plastic snap bushing found in hardware kit

into the hole left by supply cord/strain relief.

4. A licensed electrician must follow the wiring

diagram to connect incoming electrical supply

to fan kit wiring harness (see Figure 16).

5. Plug power cord to the outlet receptacle (not

provided) as shown in Figure 17. Wind the

extra cable in power cord and tie it up with

the plastic wire strap (see Figure 17). Set the

cable bundle between the burner bracket and

outer casing, away from the burner.

6. Reinstall valve cover shield.

Figure 16 - Wiring Diagram For Blower

Accessory Built-In Installation

Red

Red

Fan Switch

(Auto/Off/On)

Blue

Blue

Thermostat

Switch

(N.O.)

Green

White

Green

White

On

110/115

V.A.C.

Blower

Motor

Black

Off

1

2

3

Auto

Blower Bracket
Assembly

Screw

Wire
Harness

Power
Cord

Valve Cover
Shield

Box
Cover

Wire
Harness

Switch
Plate

Switch

Clamp
Connector
(not included)

Outlet
Receptacle

Blue

Red

Plastic Wire
Strap

Figure 17 - Installing Blower Bracket

Assembly

Extension Cord

Use extension cord if needed. The cord must have

a three-prong, grounding plug and a three-hole

receptacle. Make sure cord is in good shape. It must

be heavy enough to carry the current needed. An un-

dersized cord will cause a drop in line voltage. This

will result in loss of power and overheating. Use a

No. 16 AWG cord for lengths less than 50 feet.

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 45° male flare fitting

5/8"-18 UNF (Unified National

Fine Thread) inlet connection and

the flexible gas line provided.

WARNING: A qualified service

person must connect fireplace

to gas supply. Follow all local

codes.

7. Test to make sure the blower is working

properly.

8. Reinstall upper louver assembly and hood if

previously removed, (see Figure 13, page 12).

Close lower louver door.

Advertising