5. Place the flashing over the pipe section(s)

extending through the roof. Secure the base of

the flashing to the roof and framing with roof-

ing nails. Be sure roofing material overlaps the

top edge of the flashing as shown in Figure 19,

page 13. There must be a 1" clearance from

the vent pipe to combustible materials.

6. Continue to add pipe sections until the height

of the vent cap meets the minimum building

code requirements described in Figure 7 on

page 6. Note: You must increase vent height

for steep roof pitches. Nearby trees, adjoining

rooflines, steep pitched roofs and other similar

factors may cause poor draft or down-drafting

in high winds. Increasing the vent height may

solve this problem.

7. Twist-lock the vent cap onto the last section

of vent pipe.

Note:

If the vent pipe passes through any occupied

areas above the first floor, including storage spaces

and closets, you must enclose pipe. You may

frame and sheetrock the enclosure with standard

construction material. Make sure and meet the

minimum allowable clearances to combustibles.

Do not fill any of the required air spaces with

insulation.

VENTINg INSTALLATION

INSTRUCTIONS

Continued

Vertical Termination Configurations

Figures 21 through 24 show four different con-

figurations for vertical termination.

Venting with Two 90° Elbows

Vertical (V)

horizontal (h

1

) +

horizontal (h

2

)

' min.

' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

0' max.

8' max.

Figure 21 - Vertical Venting

Configuration Using Two 90° Elbows

with Two Horizontal Runs (Vertical

Round High Wind Termination Shown)

Note: Install restrictor

into inner collar of

fireplace as shown.

4° Elbow

Venting with One 90° Elbow
Vertical (V)

horizontal (h)

' min.

' max.

6' min.

4' max.

7' min.

6' max.

8' min.

8' max.

0' max.

8' max.

Figure 22 - Vertical Venting

Configuration Using One 90° Elbow

(Vertical Round High Wind Termination

Shown)

4° Elbow

Note: Install restrictor into
inner collar of fireplace as
shown.