SAFETy INFORMATION

Continued

3. You must keep control compartments, burn-

ers and circulating air passages clean. More

frequent cleaning may be needed due to ex-

cessive lint and dust from carpeting, bedding

material, etc. Turn off the gas valve and pilot

light before cleaning fireplace.

4. Have venting system inspected annually by

a qualified service person. If needed, have

venting system cleaned or repaired.

5. Do not use any solid fuels (wood, coal, paper,

cardboard, etc.) in this fireplace. Use only the

gas type indicated on fireplace nameplate.

6. This appliance, when installed, must be electri-

cally grounded in accordance with local codes

or, in the absence of local codes, with the

National Electrical Code, ANSI/NFPA 70 or

the Canadian Electrical Code, CSA C22.1.

7. Do not use fireplace if any part has been ex-

posed to or under water. Immediately call a

qualified service person to arrange for replace-

ment of the unit.

8. Do not operate fireplace if any log is broken.

9. Do not operate fireplace with glass door

removed, cracked or broken.

10. Provide adequate clearances around air

openings.

LOCAL CODES

Install and use fireplace with care. Follow all local

codes. In the absence to local codes, use the cur-

rent National Fuel Gas Code ANSI Z223.1/NFPA

54* (USA) or the current CSA-B149.1 Installation

Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Figure 1 - Direct-Vent Fireplace

Glass Door
Assembly

Switch Bracket for Optional
Remote and Blower

Upper Louver
Panel

Lower Louver
Panel

Flue Collar

Nailing
Flange

PRODUCT FEATURES

These are a few facts that can help you understand

and enjoy your direct-vent fireplace:

• The venting system may be routed to the out-

side of your home in several ways. It may vent

through the roof (vertical) or it may vent to an

outside/exterior wall (horizontal). The vent

pipe installation is very important to allow for

proper operation. You must follow the venting

instructions very carefully for either vertical or

horizontal applications.

• This fireplace may be installed in any room of

your house provided all local codes and these

installation instructions are followed.

• This fireplace requires a wall switch, hand-held

remote or wall thermostat (millivolt) for opera-

tion (see Accessories, page 42).

• The use of a blower requires electricity if

installed. If you plan to install the blower at a

later date, outlet at bottom of fireplace must be

wired during framing.

• Your direct-vent gas fireplace system (fireplace

and venting) is a balanced and sealed gas op-

erating unit. It requires approximately 10-20

minutes of operating time before the flame

pattern stabilizes.