Front Indicators/Connections 

 

Figure 1 TD‐6010 (left) and FOI‐6010 (right) Front Face 

 SFP Port A – Install SFPs in this slot. These slots conform to the SFP MSA (INF‐8074i more information 

later in this manual) as well as non‐MSA pinouts. They can be both fixed bi‐directional ports and support dual 
TX or dual RX SFPs. Any standard MSA or non‐MSA complaint SFP can be used in these slots including but not 
limited to optical modules with data rates in the range of 155Mbps to 12.5 Gbps, Ethernet copper modules, 
video copper modules, copper quadrax SFP to SFP cables, etc. 

Each channel is independent and will accept any format and any user supplied SFP module that is appropriate 
for the user’s equipment. Above 500 Mbps, ultra‐low jitter SFP’s are recommended (40 psec.) as well as ITU‐T 
G.652.D/IEC 60793‐2‐50.B1.3 compliant fiber optic cable. 

 SFP Port B – A second SFP slot functionally equivalent to SFP Port A. Any SFP installed in this slot will be 

directly electrically connected to the SFP in Port A. Any signals presented in the Receive of Port A will exit on 
the Transmit of Port B and vice versa.  

 TX Fault 

 RX Detect – There is one pair of these LED indicators associated with each SFP slot on the 

unit. They correspond to the slot directly below. Color indications can be interpreted using the following table: 

TX Fault 

RX Detect 

SFP Installed 

Transmitter Functioning* 

Receive Signal Present* 

Off 

Off 

No 

n/a 

n/a 

Red 

Red 

Yes 

No 

No 

Red 

Green 

Yes 

No 

Yes 

Green 

Red 

Yes 

Yes 

No 

Green 

Green 

Yes 

Yes 

Yes 

*Note that some copper Ethernet and Video SFPs may have custom TX Fault and RX Detect implementations. See SFP documentation of individual 
SFP for more information. 

 Power – LED which indicates the presence of DC power in the unit. Note that on start‐up, the unit will 

perform a quick lamp check, flashing all LEDs 

Power Indicator 

Off 

No power from the external supply or internal fault

Blue 

Power supply is operating properly

 