Table 1 - Airflow Delivery (CFM)

Airflow shown are at standard air conditions, dry coil at 120volts.

NOTES:

The cooling and heating speed taps are factory set on “A”.
The delay profile is factory set on “Arid” setting.
The adjust profile is factory set on Normal.
Adjust profile (+) will increase airflow by 10%, while tap (-) will decrease airflow by 10%.

Y1

Y2 HUM

G

O

W1

A

B

C

D

A

B

C

D

Cooling

Single Stage

X

X

X

900

775

650

525

Two Stage

X

X

X

X

630 / 900

545 / 775

455 / 650

370 / 525

Cool & Dehumidify

Single Stage

X

X

X

X

720

620

520

420

Two Stage

X

X

X

X

X

505 / 720

435 / 620

365 / 520

295 / 420

24EVBQ

Heat Pump Continuous Blower

X

450

390

325

265

Heat Pump Heating

Single Stage

X

X

900

775

650

525

Two Stage

X

X

X

630 / 900

545 / 775

455 / 650

370 / 525

Heating (Non-Ht. Pump)

Heating

X

850

735

620

500

Cooling

Single Stage

X

X

X

1300

1150

1000

850

Two Stage

X

X

X

X

910 / 1300

805 / 1150

700 / 1000

595 / 850

Cool & Dehumidify

Single Stage

X

X

X

X

1040

920

800

680

Two Stage

X

X

X

X

X

730 / 1040

645 / 920

560 / 800

475 / 680

36EVBQ

Heat Pump Continuous Blower

X

650

575

500

425

Heat Pump Heating

Single Stage

X

X

1300

1150

1000

850

Two Stage

X

X

X

910 / 1300

805 / 1150

700 / 1000

595 / 850

Heating (Non-Ht. Pump)

Heating

X

1250

1100

950

800

Cooling

Single Stage

X

X

X

1700

1550

1400

1250

Two Stage

X

X

X

X

1190 / 1700 1085 / 1550 980 / 1400

875 / 1250

Cool & Dehumidify

Single Stage

X

X

X

X

1360

1240

1120

1000

Two Stage

X

X

X

X

X

950 / 1360

870 / 1240

785 / 1120

700 / 1000

48EVBQ

Heat Pump Continuous Blower

X

850

775

700

625

Heat Pump Heating

Single Stage

X

X

1700

1550

1400

1250

Two Stage

X

X

X

1190 / 1700 1085 / 1550 980 / 1400

875 / 1250

Heating (Non-Ht. Pump)

Heating

X

1600

1450

1300

1150

Operating Mode

Model

COOL TAP

HEAT TAP

Control Board Select Taps

Thermostat Terminals

"X" Energized Terminal