3 spare parts, 4 recommended spares and consumable items, 5 disassembly – Flowserve NMD User Manual

Page 25: Flowserve

Advertising
background image

NMD, NMAD USER INSTRUCTIONS ENGLISH 71576436 - 11/09


Page 25 of 40

DIMENSIONS IN MILLIMETERS

PACKING

PUMP

D1

D2

D3

D4

D5

L1

Lgh

102 NMD –

102 NMAD

45

55

75

100 M12

45

205

10

122 NMD -
122 NMAD

55

70

95

135 M12

78

260

12

152 NMD -
152 NMAD

65

80

109 150 M16

91

297

14

202 NMD -
202 NMAD

75

100 132 180 M16 104

365

16

252 NMD

75

100 132 180 M16 104

365

16

6.2.6 Internal coating
If the pump has an internal coating, this coating
must be inspected periodically. Any wear or cracks
of the coating found must be immediately repaired.
Failure to do this may lead to accelerated wear of
the coating during operation and corrosion of the
exposed base metal, depending on the material and
pumped liquid. Special attention must be paid to the
coating edges. Any loss of coating material is
considered to be normal wear and tear on the pump
and is not considered as warranty. Flowserve has
applied the coatings according to the supplier's
instructions but will not be held responsible for
coating wear or cracks that may develop over time.

6.3 Spare parts


6.3.1 Ordering of spares
Flowserve
keeps records of all pumps that have
been supplied. When ordering spares the following
information should be quoted:

1) Pump serial number.
2) Pump size.
3) Part name
4) Part number
5) Number of parts required.


The pump size and serial number are shown on the
pump nameplate.

To ensure continued satisfactory operation,
replacement parts to the original design specification
should be obtained from Flowserve. Any change to
the original design specification (modification or use
of a non-standard part) will invalidate the pump’s
safety certification.

6.3.2 Storage of spares
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative are
recommended at 6 monthly intervals.

6.4 Recommended spares and
consumable items

[2250] - [4130] - [4590-01] – [4590-02]- [4610-01] -
[4610-02] - [4610-03] - [4610-04] - [3011] - [3300] -
[3400]

a) Destroy all the gaskets after dismantling, replace

them when reassembling.

b)

IT IS RECOMMENDED THAT

BEARINGS ARE NOT REUSED AFTER ANY
REMOVAL FROM THE SHAFT.

c) After serving during two years, replace the gland

packing.

6.5 Disassembly

Refer to section 1.6, Safety, and section 6

Maintenance, before dismantling the pump.

Before dismantling the pump for

overhaul, ensure genuine Flowserve replacement
parts are available. Refer to sectional drawings for
part numbers and identification.

REPAIR OF THE PUMP

If the pump presents abnormalities or a

persistent malfunction, contact immediately:

FLOWSERVE

After-sales Service

Tel.: 02 43 40 57 57

(33) 2 43 40 57 57

Fax.: 02 43 40 58 17

(33) 2 43 40 58 17

According to the After-sales Service instructions,
disassembly will be limited to the dismantling of the
pump.

a)

DISCONNECT THE UNIT FROM

POWER.

b) Close the inlet valve (if fitted) and outlet valve.
c) Wait for the moment when the pump casing is

cooled and at ambient temperature.

d)

DRAIN PUMP.

e) Dismantle inlet and outlet pipeworks as well as

all pipeworks.

f)

REMOVE PUMP TAKING INTO

ACCOUNT SAFETY (§ 1) AND HANDLING
(§ 3) PROCEDURES.