Flowserve Twin Screw Rotary User Manual

Page 8

Advertising
background image

TWIN SCREW PUMPS. ORIGINAL USER INSTRUCTIONS. ENGLISH. 71569243 – 07/10

Page 5 of 53

®

If the operation of the system cannot avoid this
condition the fitting of an appropriate dry run
protection device is recommended (eg liquid detection
or a power monitor).

To avoid potential hazards from fugitive emissions of
vapour or gas to atmosphere the surrounding area
must be well ventilated.

1.6.4.5 Preventing sparks

To prevent a potential hazard from mechanical

contact, the coupling guard must be non-sparking and
anti-static for Category 2.

To avoid the potential hazard from random induced
current generating a spark, the earth contact on the
baseplate must be used.

Avoid electrostatic charge: do not rub non-metallic
surfaces with a dry cloth

;

ensure cloth is damp.


The coupling must be selected to comply with 94/9/EC
and correct alignment must be maintained.

1.6.4.6 Preventing leakage

The pump must only be used to handle liquids

for which it has been approved to have the correct
corrosion resistance.

Avoid entrapment of liquid in the pump and associated
piping due to closing of suction and discharge valves,
which could cause dangerous excessive pressures to

occur if there is heat input to the liquid. This can occur
if the pump is stationary or running.

Bursting of liquid containing parts due to freezing must
be avoided by draining or protecting the pump and
ancillary systems.

Where there is the potential hazard of a loss of a seal
barrier fluid or external flush, the fluid must be
monitored.

If leakage of liquid to atmosphere can result in a
hazard, the installation of a liquid detection device is
recommended.

1.6.4.7 Maintenance to avoid the hazard

CORRECT MAINTENANCE IS REQUIRED TO

AVOID POTENTIAL HAZARDS WHICH GIVE A RISK
OF EXPLOSION
The responsibility for compliance with
maintenance instructions is with the plant
operator.

To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting
materials used must not give rise to sparking or
adversely affect the ambient conditions. Where there
is a risk from such tools or materials, maintenance
must be conducted in a safe area.

It is recommended that a maintenance plan and
schedule is adopted.(See section 6 MAINTENANCE.)

Advertising