Flowserve MSP User Manual

Page 10

Advertising
background image

MSP USER INSTRUCTIONS ENGLISH - 07/14

Page 10 of 35

dB(A) Value

63

125

250

500

1K

2K

4K

8K

4000 rpm

70

64

64

62

62

60

55

50

50

5000 rpm

72

62

66

66

64

64

64

62

57

6000 rpm

76

70

70

68

68

66

61

56

56

7000 rpm

78

68

72

72

70

70

70

68

63

8000 rpm

80

70

74

74

72

72

72

70

65

Sound pressure readings are for information only and are not subject to guarantee by Flowserve.
Decibel readings do not include driver or system noise.
Pump tested at 100% of the best efficiency point at max.impeller diameter with water.

dB correction for combining noises (pump+motor)
Difference between two
levels to be combined, dB
Add to the higher level to obtain
the combined noise level,dB

Note :
1) The values showed are measured at a distance of 1 mt. (horizontally) from major pump
surfaces and 1.5 mt. above the floor.
2) The values shown are expressed in dB.
3) For Noise Test Procedure refer to Works Standard L-109-0
4) The values shown have been derived from actual noise-test data and are based on the following conditions:

- Equipment is located in a free field above a reflecting plane in which the reductionin noise level

in all directions is 6db in each octave band for each doubling of distance.

- Background noise is 10dB minimum below all noise levels in each octave band.
- The values shown are at a distance of 1 meter (horizontally) from the major pump surface and

1,5 meters above the floor, using a standard pressure reference of 0,00002 newton per square meter.

- Overall noise level, dB(A) is determined at points of maximum noise level and the values of all

mid-band frequences are basis A scale readings.

When the required condition flow is outside the range of 75 to 125% BEP, a part load correction (PLC) must be
added to the noise level as follows:

Percent of BEP @ required

impeller diameter

PLC in

dB

74 to 62 or 126 to 136

+1

61 to 50 or 137 to 150

+2
+3
+4

37 to 25

1

0.5

0

49 to 38

3

2.5

2

1.5

Octave MID_BAND Frequency, HZ

0

1

2

4

6

9

10

Advertising