Drawings (8), General assembly drawings (8), Parts lists (8) – Flowserve Mark 3 ISO Durco User Manual

Page 26: Sectional drawings (8)

Advertising
background image

DURCO MARK 3 ISO CLOSE COUPLED ENGLISH 26999985 02-14

Page 26 of 32

flowserve.com

FAULT SYMPTOM

P u m p o v e r h e a t s a n d s e i z e s

B e a r i n g s h a v e s h o r t l i f e

P u m p v i b r a t e s o r i s n o i s y

M e c h a n i c a l s e a l h a s s h o r t l i f e

M e c h a n i c a l s e a l l e a k s e x c e s s i v e l y

P u m p r e q u i r e s e x c e s s i v e p o w e r

P u m p l o s e s p r i m e a ft e r s t a r t i n g

I n s u f f i c i e n t p r e s s u r e d e v e l o p e d

I n s u f f i c i e n t c a p a c i t y d e l i v e r e d

P u m p d o e s n o t d e l i v e r l i q u i d

PROBABLE CAUSES

POSSIBLE REMEDIES

Rotating part rubbing on stationary part internally.

Check and CONSULT FLOWSERVE, if necessary.

Bearings worn

Replace bearings.

Impeller damaged or eroded.

Replace or CONSULT FLOWSERVE for improved
material selection.

Stub shaft worn or scored or running off center.

Check and renew defective parts.

Mechanical seal improperly installed.

Check alignment of faces or damaged parts and
assembly method used.

Incorrect type of mechanical seal for operating
conditions.

CONSULT FLOWSERVE.

Shaft running off center because of worn bearings
or misalignment.

Check misalignment and correct if necessary. If
alignment satisfactory check bearings for excessive
wear.

Impeller out of balance resulting in vibration.

Check and CONSULT FLOWSERVE.

Abrasive solids in liquid pumped.

Internal misalignment of parts preventing seal ring
and seat from mating properly.

Mechanical seal was run dry.

Check mechanical seal condition and source of dry
running and repair.

Internal misalignment due to improper repairs
causing impeller to rub.

Check method of assembly, possible damage or
state of cleanliness during assembly.
Remedy or CONSULT FLOWSERVE, if necessary.

Excessive thrust caused by a mechanical failure
inside the pump.

Check wear condition of impeller, its clearances and
liquid passages.

Damaged bearings due to contamination.

Check contamination source and replace damaged
bearings.

C. Motor electrical problems

Wrong direction of rotation.

Reverse 2 phases at motor terminal box.

Motor running on 2 phases only.

Check supply and fuses.

Motor running too slow.

Check motor terminal box connections and voltage.

Motor incorrectly wired.

Check motor terminal box connections, refer to
motor instructions.

Advertising