2.7 Install the compression unit 45 for the inner seal on the sleeve and locate

the collar 5 in relation to the established scribe mark C, the setting dimen-

sion given on the seal assembly drawing. Lock the collar to the sleeve by

tightening the set screws S .

2.8 Place the seal ring 3 and shaft packing P for the inner seal on the sleeve

and in its proper position as shown. (Duraflon

®

shaft packing should be

installed on the sleeve individually and with care to avoid nicks or damage

that could cause a leak.)

2.9 Place the stationary insert 2 and insert mounting 6 for the inner seal on

the sleeve.

2.10 Wipe the face of the seal ring and stationary insert clean with alcohol.

2.11 Install the compression unit 45 and/or collar 5 for the outer seal on the

sleeve and locate the collar 5 at the established scribe mark B. Lock the

collar to the sleeve by tightening the set screws S .

2.12 Place the seal ring 3A and shaft packing P1 for the outer seal on the

sleeve and in its proper position as shown. (Duraflon

®

shaft packing should

be installed on the sleeve individually and with care to avoid nicks or dam-

age that could cause a leak.)

2.13 Wipe the face of the seal ring and stationary insert clean with alcohol.

Note: If the outer seal is mounted on the shaft rather than on the shaft sleeve, it

will be necessary to substitute the following installation instructions for the

above:

2.11A Place the outer seal ring 3A and shaft packing P1 on the shaft and in

its proper position. (Duraflon

®

shaft packing should be installed

individually and with care to avoid nicks and damage that could cause a

leak.)

2.12A Wipe the face of the seal ring and insert clean with alcohol.

2.13A Install the compression unit 45 and/or collar 5 for the outer seal on

the shaft and locate the collar at the established scribe mark B. Lock

the collar to the shaft by tightening the set screws S . Then place the

insert holder IH over the shaft and into its proper position in the gland

ring as shown on the seal assembly drawing.

2.14 While placing the sleeve into its proper position over the shaft, position the

inner stationary insert 2 into the insert holder IH , making sure to align the

insert holding pin with the slot or hole in the insert holder if one is included.

® Registered Trademark of Flowserve Corporation