Step 4a With the setting devices against

the box face, tighten the set

screws. Seal sizes up to 101.6 mm

(4.000 inch) have four set screws

all at one joint while larger sizes

have an additional two set screws

at the opposite joint. Tighten all set

screws to 25 in-lbs for seal sizes

up 50.8 mm to (2.000 inch) and

50 in-lbs for larger sizes. For seal

sizes above 152.4 mm (6.000 inch),

refer to seal assembly drawing for

number of set screws and torque

specifications.

b Tighten set screws a second

time

in the same succession.

Step 5 Pry off the seal drive setting

devices

with a screwdriver.

Step 6a Lubricate the seat gasket ends

and exposed surfaces of the

gland split joint gaskets with the

enclosed lube.

b Carefully assemble the gland

halves around the rotor.

c Finger tighten the gland cap

screws. There should be a gap

between the halves of about

0.8 mm (.03 inch).

d Finger tighten the gland bolts so

the gland is supported at the

pump mounting surface while

the cap screws are being

tightened.

e Tighten the gland cap screws

to 12 ft-lbs minimum.

f Tighten the gland mounting

bolts evenly until the gland

gasket is fully compressed and

the gland is squarely seated

against the pump box face. This is

approximately 25 ft-lbs torque.

Step 4

Step 5

Step 6