4 operational recommendations – Flowserve GCX Series User Manual

Page 10

Advertising
background image

10

3 Single Seal Piping and Operational Recommendations

3.1 Install an adequate seal flush system. The GCX requires a clean

cool environment for maximum seal life. With a clean cool product,

use a bypass flush from the pump discharge (Plan 11) or a bypass

flush to the pump suction (Plan 13). With clean hot products

use a bypass flush through a cooler (Plan 21). With abrasive

products or products that are incompatible with the seal, use a flush

from a clean external source (Plan 32). Consult your Flowserve

Representative for assistance with choosing the appropriate flush

system.

3.3 Taps in the gland are quench and drain ports used for fluid

quenching, Plan 62. If they are not used, they should be plugged

with pipe plugs.

3.4 Remove lock outs on pump and valves.
3.5 Do not start up the equipment dry to check motor rotation or for any

other reason. Open valves to flood pump with product fluid. Ensure

that the seal flush system is operating. Vent air from the casing of

the pump and the seal chamber before start-up.

3.6 Observe the start-up. If the seal runs hot or squeals, check the seal

flush system. Shut down the equipment immediately if the seal

becomes hot or squeals.

4 Operational Recommendations

4.1 Do not exceed corrosion limits. The GCX is designed to resist

corrosion by most chemicals. However, do not expose the GCX

materials of construction to products outside of their corrosion limits.

The GCX assembly drawing lists the materials of construction.

Consult your Flowserve Representative for chemical resistance

recommendations.

4.2 Do not exceed the recommended maximum pressure and speed

limits of 13.8 bar (200 psi) and of 3600 rpm.

4.3 Do not exceed the temperature limit of 204°C (400°F).
4.4 Do not start up or run the GCX dry. Process fluid must be in the

pump volute at all times during seal operation.

For special problems encountered during installation, contact your nearest

Flowserve Sales and Service Representative or Authorized Distributor.