2 GCX Installation

Note: The GCX seal is shipped with the sleeve and gland graphite

gaskets uninstalled. These parts must be assembled onto the seal prior

to installation of the seal into the pump. The gaskets are very fragile;

handle with care.
Note: No seal setting measurements are needed to install the

seal. Instructions are for radially split case end-suction ANSI pumps.

Modification of the procedure may be required for other style pumps.

Consult your Flowserve Representative.
2.1 Tools needed for installation:

• An open end wrench for the gland bolt nuts

• 5/16” open end wrench for the collar bolts

• 3/32” Allen wrench (provided)

• 1/8” Allen wrench (provided)

2.2 Loosen the collar cap screws and remove the drive collar from

the seal assembly.

2.3 Install the sleeve

gasket into the drive

collar. Do not use any

sharp instruments

for installation of the

gasket. Loosely reattach

the collar and gasket

assembly to the seal

with the collar bolts.

See Figure 4.

2.4 Adhere the gland gasket to the gland centered on the register.

Dabs of silicone grease or a spray adhesive may be used to hold

the gasket in place.

2.5 Lubricate the shaft or sleeve lightly with silicone lubricant unless

otherwise specified.

2.6 Tighten the Centering Tab screws.