Cleaning and repairs – Flowserve Seal Gard User Manual

Page 7

Advertising
background image

7

The optional alarm features can also be set to respond to a high or low flow or

both high and low flows as needed. Two alarm probes are required to respond

to both high and low flows. With this arrangement, the low flow alarm indicates

inadequate flow to the seal. The high flow alarm indicates that the inner seal is

leaking seal barrier or buffer fluid into the product. Close the Seal Gard return-

from-seal valve and reset the supply control valve to minimize product dilution

until the seal can be scheduled for repair.

4. Cleaning and Repairs

4.1 To clean the Seal Gard:

shut down the pump or provide a bypass flush system to the

Flowserve seal.

close the valve from the flush fluid supply line to Seal Gard.

relieve any pressure on the Seal Gard.

remove the threaded cap(s) from the top of the flow tube(s).

clean the flow tube(s) using soap and water. (Steam and alcohol will

turn the acrylic resin white and make the meter unreadable).

re-install the threaded cap(s) making sure that the float(s) is in

position.

open inlet valve to renew flow to the seal

adust flow control valves as indicated in steps 3.2 or 3.3.

4.2 To repair the Seal Gard:

shut down the pump or provide a bypass flush system to the

Flowserve seal.

close the valve from the flush fluid supply line to Seal Gard.

relieve any pressure on the Seal Gard.

disconnect pipe connections and remove the Seal Gard from its

mounting.

remove the threaded cap(s) from the top of the flow tube(s).

clean the flow tube(s) using soap and water. (Steam and alcohol will

turn the acrylic resin white and make the meter unreadable).

replace the float(s), valve(s), and O-rings (repair kit available).

re-install Seal Gard to its mounting and reconnect piping.

re-install the threaded cap(s) making sure that the float(s) is in

position.

open inlet valve to renew flow to the seal

adust flow control valves as indicated in steps 3.2 or 3.3.

A Seal Gard can normally be reconditioned. Return the Seal Gard to Flowserve

Corporation with an order marked "Repair or Replace." It will be inspected and, if

repairable, it will be rebuilt, tested, and returned in its original condition.

Advertising