Use of the Seal Gard to troubleshoot sealing system problems

Type of

Observation

Cause

Suggested Action

Installation

Flowserve seal

Seal Gard I

Single

• no flow in tube

• seal fluid flow

• check supply pressure

• low flow alarm

interrupted

• clean control valve

• pressure

• correct back pressure

reversal

problem

Seal Gard II

Double

• no flow in tube

• seal fluid flow

• check supply pressure

• low flow alarm

interrupted

• clean control valves

• low pressure

• high pressure

• pressure

• correct back pressure

reversal

problem

• high flow alarm

• inner seal

• close return-from-seal

• low pressure

failure

control valve

• adjust supply control

valve to acceptable

dilution & schedule

seal repair

Seal Gard II

Tandem

• no flow in tube

• seal fluid flow

• check flush source

• low flow alarm

interrupted

• high pressure

• primary (inner) • close supply control

• product in outlet seal failure

valve

• adjust return-from-

seal valve to accept-

able loss level

• route discharge to

approved disposal

• schedule seal repair

8