Description, 1 equipment check, Seal chamber requirements – Flowserve P-200 Durametallic User Manual

Page 2

Advertising
background image

2

Description

This P-200 seal is a dual, cartridge mounted, end face mechanical seal,

designed for ease of installation. No seal setting dimensions are

required. Removable setting devices provide proper alignment.

Installation according to the following steps will ensure a long

trouble-free life of the P-200 seal.

1 Equipment Check

1.1 Follow plant safety regulations prior to equipment disassembly:

• Lock out motor and valves.

• Wear designated personal safety equipment.

• Relieve any pressure in the system.

• Consult plant MSDS files for hazardous material regulations.

Seal Chamber Requirements

Figure 1

To first obstruction

Face of seal housing to be square to the

axis of the shaft to within 0.0005 mm/mm

(0.0005 inch/inch) of seal chamber bore TIR

and have a 1.6

μ

m (63

μ

inch) R finish or better

a

Gland pilot can be at either of these

register locations, concentric to within

0.125 mm (0.005 inch) of shaft or

sleeve OD TIR

Seal housing bore to have 3.2 μm

(125 μinch) R finish or better

Sleeve or shaft finish to be

0.8 μm (32 μinch) R or better

a

a

• Bearings must be in good condition

• Maximum lateral or axial movement of shaft (end play) = 0.25 mm (0.010 inch) TIR

• Maximum shaft runout at face of seal housing = 0.05 mm (0.002 inch) TIR

• Maximum dynamic shaft deflection at seal housing = 0.05 mm (0.002 inch) TIR

Shaft or sleeve OD

+0.000 mm (+0.000 inch)

-0.050 mm (-0.002 inch)
+0.000 mm (+0.000 inch) API 610/682

-0.025 mm (-0.001 inch) DIN/ISO

ANSI

The images of parts shown in these instructions may differ visually from the actual

parts due to manufacturing processes that do not affect the part function or quality.