Note: No seal setting measurements are needed to install the CPM
PP seal. Instructions are for vertically split case end-suction ANSI
pumps. Modification of the procedure may be required for other
style pumps. Consult Flowserve.
2.1 Tools needed for installation:
• An open end wrench for the gland bolt nuts
• 1/8" and 3/16" hex wrench (provided)
• 5/16" and 3/8" open end wrench (provided)
• Silicone Lubricant
2.2 Lubricate the shaft or sleeve
lightly with silicone lubricant.
2.3 Install the complete CPM PP
cartridge assembly onto the
shaft or sleeve with the setting
devices 103 near the bearing
housing. See Figure 3.
2.4 Install the pump back plate
(seal chamber) and bolt it in
place on the bearing frame.
See Figure 4.
Figure 3
Figure 4