2cpm pp installation – Flowserve CPM Series User Manual

Page 6

Advertising
background image

6

2

CPM PP Installation

Note: No seal setting measurements are needed to install the CPM

PP seal. Instructions are for vertically split case end-suction ANSI

pumps. Modification of the procedure may be required for other

style pumps. Consult Flowserve.

2.1 Tools needed for installation:

• An open end wrench for the gland bolt nuts

• 1/8" and 3/16" hex wrench (provided)

• 5/16" and 3/8" open end wrench (provided)

• Silicone Lubricant

2.2 Lubricate the shaft or sleeve

lightly with silicone lubricant.

2.3 Install the complete CPM PP

cartridge assembly onto the

shaft or sleeve with the setting

devices 103 near the bearing

housing. See Figure 3.

2.4 Install the pump back plate

(seal chamber) and bolt it in

place on the bearing frame.

See Figure 4.

Figure 3

Figure 4

Advertising