6.0 DISASSEMBLY

(Continued)

6.1.3 Electric Motor Actuators

Although various types of electric motor actuators (Fig. 10) are supplied, all follow the same pattern with their removal
from the valve. Prior to the removal, all power and control wiring should be disconnected from the actuator. With the
stem protector (334) and capscrews (218) removed, and the actuator properly supported, it can be raised in the same
manner as the gear unit.