5 disassembly of 5:1 spur gear attachment for mt-4, 6 reassembly of 5:1 spur gear attachment for mt-4 – Flowserve MT Bevel Gearboxes IOM User Manual

Page 25

Advertising
background image

25

Limitorque MT Series FCD LMENIM4201-00 – 06/10

flowserve.com

6.4.5 Disassembly of 5:1 Spur Gear Attachment for MT-4

(Piece numbers refer to Figure 6.7 and Table 6.7).

1. Remove the Socket Head Cap Screws (piece #217) and Lockwashers (piece #216) to remove the

Housing (piece #201).

2. Remove the Housing complete with the Input Shaft and Pinion (piece #202) and Idler Gear

(piece #203).

3. Remove the Hex Head Cap Screw (piece #215), Lockwasher (piece #214), and Flat Washer

(piece #213).

4. Remove the Output Gear (piece #204).

5. Remove the Hex Head Cap Screw (piece #218) and Lockwasher (piece #216).

6. Remove the Adapter Plate (piece #200) and O-ring (piece #211).

7. Continue disassembly as detailed in Section 6.2, Disassembly and Reassembly of MT-4.

6.4.6 Reassembly of 5:1 Spur Gear Attachment for MT-4

(Piece numbers refer to Figure 6.7 and Table 6.7).

1. Install the O-ring (piece #211) and Adapter Plate (piece #200), using the Hex Head Cap Screws

(piece #218) and Lockwashers (piece #216).

2. Install the Output Gear (piece #204).

3. Install the Flat Washer (piece #213), Lockwasher (piece #214), and Hex Head Cap Screw

(piece #215).

4. Install the Idler Gear (piece #203) and the Input Shaft and Pinion (piece #202) into the Housing

(piece #201).

5. Apply liquid gasket to the Adapter Plate flange and install the Housing assembly (piece #210, #202,

and #203), using the Socket Head Cap Screws (piece #217) and Lockwashers (piece #216).

Advertising