Operation – Flowserve EV 30 User Manual

Page 22

Advertising
background image

22

Operation

Opening the loading and unloading system EV 30

See Fig. 1, 3, 5

1. Turn locking hook clockwise upwards to unlock the hand lever .

2. After unlocking the hand lever pull the latter with both hands towards the

indicator until they are firmly interlocked.

3. Release the locking hook and open the bottom valve with the interlocking vent

valve by pulling down the hand lever. In this position the locking hook will
automatically engage at the rear of the locking guide , thereby keeping the
valves open.

4. The indicator visually indicates on both sides of the tank car that the valves

are open.

Closing the loading and unloading system EV 30

See Fig. 1, 3, 5

Attention

Note that hand lever is spring-loaded. In case of improper handling the
lever may spring upwards.

1. Push hand lever in the opening position. Turn the locking hook clockwise

upwards until the hook disengages from the locking guide .

2. Move the hand lever slowly upwards to close the valve system.

3. Push back hand lever with both hands (disengaging indicator ) until the

locking hook engages.

4. The indicator visually indicates on both sides of the tank car that the valves

are closed.