Flowserve 191400 Series User Manual

Page 4

Advertising
background image

4

3.1

Application

Control Valve

3.2

Pressure rating

PN 25 ( depending on body

connection)

3.3

Temperature range

0 °C to 100 °C

3.4

Valve function

To ensure optimum valve function, observe the flow

direction from connection a to connection b.

3.4.1 Function: air-to-open – spring-to-close

Product flow direction ab (see fig. 1)

Product flow direction closed by spring force.

3.4.2 Function: spring-to-open – air-to-close

Product flow direction ab (see fig. 1)

Product flow direction closed by air force.

3.5 Material data

Seals in contact with the medium

Valve plug

1.4435

Operating temperature

max. 100° C

Sterilisation temperature

130° C

Operating pressure

max.25 bar

Seals not in contact with the medium

O-Rings

Silicon

Stainless steels

In contact with the medium

1.4404 / 1.4435 (316L)

Not in contact with the medium 1.4301

3.6 CIP cleaning agents

Nitric acid 3% / Temperature 80° C
Soda lye 3% / Temperature 80° C

3.7 SIP sterilisation agents

Hot water / Temperature 130° C
Steam / Temperature 130° C

3.8 Surfaces

In contact with medium

Ra ≤ 0,6 µm

Ra ≤ 0,5 µm Elec.-polished (opt.)

Ra ≤ 0,4 µm Elec.-polished (opt.)

Not in contact with medium Metal, turned bright

3.9 Valve connection piping

Installation position
Vertical, to ensure valve and line drain free.

3.10 Connection types

DIN 11850 series 2 (DN10 - 100) weld ends

ISO 2037 / BS 4825 weld ends

DIN EN ISO 1127 weld ends

DIN 11851 threaded connection

DIN 11864 Form A threaded connection

DIN 11864 Form A flange connection

DIN 2526 flange connection PN 10

DIN 32676 clamp connection

ISO 2852 clamp connection

3.11 Pipe connection

Separable (for disassembly).

3.12 Welding instruction

See welding instructions (sec. 5.4).

3.13 Installation

See assembly and disassembly instructions (sec. 6).

3.14 Electrical and pneumatic connections

Assemble after fitting the valve.

3.14.1 Electrical connections

WARNING: Electrical connections to be made by a

qualified electrician only.

• Observe valid VDE-EVU and other local regulations.

• Check operating voltage and amperage of specific

parts before connection.

3.15 Quality of supply air

Pressure

6 bar

Solid particles

Particle size max. 5 mm (0.4inch)

Particle density max. 5 mg/m

3

(quality class 3)

Water content

Dew point +2° C

(quality class 3)

Oil content

Oil free, max. oil content

25 mg/m

3

(quality class 3)

STOP!