SECTION VII

RECOMMENDED SPARE PARTS

Named parts shown below by respective valve are recommended
spare parts for that valve model.

Design, Manufacture, and In-house Repair

of Ball, Butterfly and Plug Valves

in Cookeville, TN

GROUND SPRING

DIAPHRAGM

SLEEVE

G4 MARATHON VALVE

GROUND
SPRING

TEFLON
BACK-UP
RINGS (2)

0-RINGS (2)

THRUST COLLAR/
DIAPHRAGM
ASSEMBLY
CD4M/C276

G4Z & G4ZHF FIRESAFE VALVE

Selection, Installation, Operation and Maintenance

Flowserve Corporation has established industry leadership in the design and manufacture of its products. When

properly selected, each product is designed to perform its intended function safely during its useful service life. However,
it is necessary that Flowserve’s customers be fully aware of their responsibilities when using these products.

Each Flowserve valve product may be used in numerous applications under a wide variety of industrial service

conditions. Although Flowserve can, and often does, provide general guidelines, it is obviously not possible to provide
application specific data and warnings for all conceivable applications. The purchaser/end user must therefore assume
the ultimate responsibility for the proper selection, installation, operation and maintenance of the products. Read the
appropriate IOM before installation, operating or repairing any valve. The purchaser/end user should train its employees
and/or contractors in the safe use of the Flowserve products in connection with the purchaser’s manufacturing processes.

Flowserve will continue to provide its customers with the best possible products and service available. We do not

recommend substituting surplus or remanufactured valves over new Durco valves or those repaired in an authorized
service center. Should you have any questions about these provisions or about Flowserve’s products in general, please
contact your local Flowserve valve representative, who will be happy to help.

For more information, contact:

Flowserve Corporation
Flow Control Division
1978 Foreman Drive
Cookeville, Tennessee 38501
Phone: 931 432 4021
Fax: 931 432 3105
www.flowserve.com

DIAPHRAGM
(STAINLESS
STEEL OR
MONEL)
GASKET

(GRAFOIL)
PACKING

(GRAFOIL)
DIAPHRAGM

(PFA)
SLEEVE

TEFLON BACK-UP RINGS (2)

O-RINGS (2)

THRUST COLLAR/
DIAPHRAGM ASSEMBLY