8. To remove fan motor assembly

(1) Remove two screws

¤

which secure the back cover

¤Ł

from the cavity outer

.

(2) Remove two screws

¤Ø

which secure the fan motor

¤Œ

from the back cover

¤Ł

.

(3) Pull out the fan

¤º

from the fan motor

¤Œ

.

(4) Reverse the above steps for reassembly.

9. To remove transformer

(1) Remove the two screws

¤

holding the H.V. trans-

former

¤Ł

.

(2) Remove the transformer

¤Ł

.

(3) Reverse the above steps for reassembly.

Filament
Terminal

Cooling Fin

Magnetron
Antenna

Magnetron

Metallic
Gasket
Plate

Metallic Gasket Plate

Magnetron Antenna

Wave Guide

5

4

1

3

1

2

CAUTION : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to

prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave
leakage. It shall not exceed 4mW/cm

2

for a fully assembled oven with door normally closed.