Component test procedure – Daewoo KOR-61151 User Manual

Page 24

Advertising
background image

24

1. High voltage is present at the high voltage terminal of the voltage transformer during any cooking cycle.
2. It is neither necessary nor advisable to attempt measurement of the high voltage.
3. Before touching any oven components or wiring, always unplug the oven from its power source and discharge the

capacitor (see page 13).

COMPONENT TEST PROCEDURE

1. High voltage transformer

(A) Remove connections from the transformer terminals

and check continuity.

(B) Normal readings should be as follows:

Secondary winding

Approx. 150

¡

10%

Filament winding

Approx. 0

Primary winding

Approx. 0

2. High voltage capacitor

(A) Check continuity of capacitor with meter on the

highest OHM scale.

(B) A normal capacitor will show continuity for a short

time, and then indicate 9M

once the capacitor is

charged.

(C) A shorted capacitor will show continuous continuity.
(D) An open capacitor will show constant 9M

.

(E) Resistance between each terminal and chassis should

be infinite.

3. High voltage diode

(A) Isolate the diode from the circuit by disconnecting the

leads.

(B) With the ohmmeter set on the highest resistance

scale, measure the resistance across the diode
terminals.
Reverse the meter leads and again observe the
resistance reading. Meter with 6V, 9V or higher
voltage batteries should be used to check the front-
back resistance of the diode, otherwise an infinite
resistance may be read in both directions. A normal
didoes resistance will be infinite in one direction and
several hundred K

in the other direction.

4. Magnetron

For complete magnetron diagnosis, refer to “Measure-
ment of the Microwave Output Power”. (Page 8)
Continuity checks can only indicate and open filament
or a shorted magnetron.
To diagnose for an open filament or shorted magnetron,

(A) Isolate magnetron from the circuit by disconnecting

the leads.

(B) A continuity check across magnetron filament termi-

nals should indicate 0.1ohm or less.

(C) A continuity check between each filament terminal

and magnetron case should read open.

5. Fuse

If the fuse in the primary and monitor switch circuit is
blown when the door is opened, check the primary and
monitor switch before replacing the blown fuse. In case
the fuse is blown by an improper switch operation,
replace the defective switch and fuse at the same time.
Replace just the fuse if the switches operate normally.

CAUTION : REPLACE BLOWN FUSE WITH 15

AMPERE FUSE.