(2) Secondary interlock switch and interlock monitor switch

When the door is closed, the hook pushes the push lever downward, the push lever presses the button of the interlock
monitor switch to bring it under “OFF”, condition and presses the button of the secondary interlock switch to bring it
under “ON”, condition.

Adjustment 2

Interlock monitor switch

When the door is closed, the interlock monitor switch should be opened before other switches close.
When the door is opened, the interlock monitor switch should be closed after other switches open.

Secondary interlock switch

The movement of the switch button should exceed 1.2mm measured at the top of the button.

(3) Adjustment steps

a) Loosen the two mounting screws.
b) Adjust interlock switch assembly position.
c) Confirm the gap (1.2mm) described above.
d) Make sure that push lever moves smoothly after adjustments is completed.
e) Completely tighten the two mounting screws.

(4) Interlock switch replacement

Whenever safety interlock switch are replaced:
1) Refer to the following diagram.
2) Check the connection of monitor switch after replacement.
3) Perform the electrical continuity check of interlock switches and microwave emission test mentioned in this manual.

Interlock
Monitor
Swtich

Push Lever

Hook

Secondary
Interlock
Switch

NOTE : Microwave emission test should be performed after adjusting interlock machanism. If the microwave

emission exceed 4mW/cm

2

, readjust interlock mechanism.

Secondary
Interlock
Switch

BL

RD

WH

WH

WH

WH

BK

Interlock
Monitor
Switch

Primary
Interlock
Switch

RD

RD

RD

SYMBOL

COLOR

RD

RED

WH

WHITE

BK

BLACK

BL

BLUE

Advertising