6. Install the End Cap (pc# 6) and Gasket (pc# 22).

7. Insert the Worm Shaft (pc# 3) into the Housing bore.

8. Install the Tapered Roller Bearing (pc# 11) onto the Worm Shaft in the Housing bore.

9. Replace the Oil Seal (pc# 19) in the Input Flange (pc# 7), if required.

10. Install the Input Flange (pc# 7) with Gasket (pc# 22) or install the Spur Gear Attachment (See Section 4.5 or 4.6).

Note:

Lubricate the worm gear mesh to replace lubricant lost during disassembly

(see Lubrication, Section 3).

11. Place the upper Thrust Washer (pc# 9) on the Worm Gear/Drive Sleeve (pc# 5).

12. Replace the upper O-Ring (pc# 20) in the Housing Cover (pc# 2).

Note:

Lubricate all O-Rings before installation.

13. Install the Housing Cover (pc# 2) with Cover Gasket (pc# 21).

14. Replace the upper O-Ring (pc# 18) in the Housing Cover (pc# 2).

15. Replace the Pointer Cap O-ring (pc# 31) in the top of the Worm Gear/Drive Sleeve (pc# 5).

Note:

Lubricate all O-Rings before installation.

16. Install the Pointer Cap (pc# 8).

17. Turn the operator upside

down and insert the Splined
Adapter (pc# 4).

18. Install the Splined Adapter

Retaining Ring (pc# 10).

4

29 14

30 12

28 13

8

31

18

2

21

20

9

5

9

6

22

11

24

1

3

32
23

16

15

27

13

28

11

22

19

7

17

17

10

(VARIES)

PC-7 IS REPLACED BY

OPTIONAL SPUR GEAR

ATTACHMENT, IF SUPPLIED

Figure 4.2 –

WG-00 through WG-35 Exploded View

Advertising