Flowserve WG Series Limitorque User Manual

Page 9

Advertising
background image

9

Limitorque WG Series Worm Gear Operator FCD LMENIM2101-02 – 1/15

flowserve.com

2.6 Setting Position Limit Stops – WG-00 Through WG-12

Refer to Figure 2.4

1. Loosen the Hex Nut (pc# 16) and turn it several turns to allow for stop screw adjustment.

2. Adjust the Stop Screw by turning it counterclockwise to back the screw away from the Worm Gear/Drive Sleeve (pc# 5).

3. Place the valve disk in the full closed position.

4. Turn the Stop Screw (pc# 15) in the clockwise direction until the end of the screw contacts the Worm Gear/Drive Sleeve.

5. Tighten the Hex Nut to secure the closed set position.

6. Move the valve disk to the full open position.

7. Follow steps 1 through 5.

a

CAUTION: If the valve is operated with an electric actuator/gear operator combination, and the valve is position-seated,
set the actuator limit switches to trip prior to engagement of the WG Worm Gear/Drive Sleeve with the Stop Screws.
Damage to the operator could result from the Worm Gear/Drive Sleeve contacting the Stop Screw under motorized
operation.

Note: The stops are adjustable to +/- 5º of total travel to allow for proper positioning

of the worm gear quadrant.

Figure 2.4 – Setting Position Limit Stops – WG-00 through WG-12

21

2

20

8

17

17

10

9

27

24

25

3

7

19

22

11

1

11

22

6

5

32

23

16

15

4

31 18

14 29

12

9

30

28 13

28 13

Advertising