AXAIM020-01

(AUTO-48)

3/03

Page 12 of 16

© 2003, Flowserve Corporation, Printed in U.S.A.

BUSwitch

with F

OUNDATION

®

Fieldbus Protocol

Installation, Operating and Maintenance Instructions

Flowserve Corporation

1350 N. Mountain Springs Parkway

1978 Foreman Dr.

Flow Control Division

Springville, Utah 84663-3004

Cookeville, TN 38501

www.flowserve.com

Phone: 801 489 8611

Phone: 931 432 4021

Rel.
Index

Parameter

Factory
Default

Description

25

OPERATION

Note 1

Configures the piezo/coil element terminals for single coil or dual
coil modes.

26

OUTPUT_CONFIGUR
ATION

Note 1

Configures the piezo/coil signals to shut-off or remain continuous
after TIME_OUT period. Applies to Dual Coil mode only.

27

ODOMETER

This variable counts the transitions from open to closed and
closed to open states. It is reset-able to 0, after maintenance.

28

RESET_ODOMETER

Resets the ODOMETER counter.

29

FAILURE_RECOVERY

Enable/Disable FAILURE_RECOVERY action.1: Act with or
without change in the input, 2: Do not act until a new change in the
input.

30

RESET_TIMEOUT

Resets a TIME_OUT occurrence.

31

TRANSITION_TIME

How much time for the last transition.

32

TIME_OUT

10

The time allowed for a transition before the DI associated with the
TIME-OUT Alarm is Activated. Also, the length of the One-Shot
pulse voltage output to the coils in the Dual Coil Operation Mode.

33

SOLENOIDE_CLOSED

SW1 state

34

SOLENOIDE_OPEND

SW2 state

35

TRANSITION_ALARM

DI1 state = transition TIME-OUT state

36

EXTERNAL_ALARM

DI2 state = It read the status of the Temperature/Pressure Limit
(CN1.12 pin) Data is passed on to DI2.

37

ACTION_TIME

Time since last command for transition.

Notes:
1. Selected by Factory in accordance with customer PO specifications.

Transducer Block Parameter Specifications

Rel.

Index

Parameter Mnemonic

Data

Type

Size

Valid

Range

Units

Class

1

ST_REV

Unsigned 16

2

Positive

N/A

Read

2

TAG_DESC

Visible String

32

String Data

N/A

R/W

3

STRATEGY

Unsigned 16

2

N/A

R/W

4

ALERT_KEY

Unsigned 8

1

1-255

N/A

R/W

5

MODE_BLK

DS-69

4

N/A

R/W

6

BLOCK_ERR

Bit String

2

N/A

Read

7

UPDATE_EVT

DS-73

5

N/A

Read

8

BLOCK_ALARM

DS-72

13

N/A

Read

9

TRANSDUCER_DIRECTORY

Unsigned 16

Array

Variable

N/A

Read

10

TRANSDUCER_TYPE

Unsigned 16

2

E

R/W

11

XD_ERROR

Unsigned 8

1

N/A

Read

12

COLLECTION_DIRECTORY

Unsigned 32

Array

Variable

N/A

13

FINAL_VALUE_D

DS-66

2

N/A

R/W

14

ACT_FAIL_ACTION

Unsigned 8

1

0=Undefined

1=Close

2=Open

3=Last

E

R/W

R/W

R/W

15

ACT_MAN_ID

Unsigned 32

4

E