Maintenance
– continued –
Torques
All torques are based at 0 °C room temperature.
. Observe danger note on page 4!
. Unscrew sealing plug
J
and remove strainer
H
.
. Clean strainer, sealing plug and gasket seats.
4. Replace strainer and sealing plug in case of visible signs of wear or damage.
5. Replace gasket
I
if damaged.
6. Apply heat-resistant lubricant to the thread of the sealing plug (use for instance WINIX
®
50).
7. Install sealing plug
J
with gasket
I
and strainer
H
. Tighten sealing plug with a torque
of
120 Nm.
Cleaning / replacing the strainer
Tools
■
Spanner A. F. 6 mm to DIN , form B
■
Spanner A. F. mm to DIN , form B
■
Spanner A. F. 0 mm to DIN , form B
■
Torque spanner 0 – 0 Nm, ISO 6789
WINIX
®
50 is a registered trademark of WINIX GmbH, Norderstedt
Item
Designation
Torque [Nm]
D
Regulator
0
90
A
Body screws
0
5
J
Sealing plug
0