Technical data – Flowserve NRGS 11-2 User Manual

Page 6

Advertising
background image

6

NRGS 11-2, NRGS 16-2

continued

Technical Data

continued

Lengths supplied

500 mm
000 mm
500 mm

Mains supply

230 V +/– 0 %, 50/60 Hz
5 V +/– 0 %, 50/60 Hz
24 V +/– 0 %, 50/60 Hz (option)

Power consumption

5 VA

Fuse
Thermal fuse T

max

= 02 °C

Sensitivity

Range : 0 µS/cm
Range 2: 0.5 µS/cm
Electrode voltage

0 V

ss

Output

4 volt-free relay contacts for low level alarm,  normally open contact (e.g. for pump).

Max. contact rating with a switching voltage of 24 V, 5 V and 230 V a. c.: resistive 4 A,

inductive 0.75 A at cos

ϕ 0.5.

Max contact rating with a switching voltage of 24 V d. c.: 4 A.

Contact material: silver, hard-gold plated.
Indicators and adjustors

2 red LEDs for signalling “Low water”,

 green LED for signalling “Pump ON”,

 four-pole code switch for changing sensitivity,

 button “TEST” for checking low-level alarm

 button “RESET” for resetting the low-level alarm
Cable entry
Cable gland with integral cable clamp

M 6 (PG 9)
M 20 (PG 6)

Protection
IP 65 to DIN 40050

Max. admissible ambient temperature

70 °C
Weight

approx. 0.8 kg

Advertising