Pressure/temperature rating – Flowserve BK 212 User Manual

Page 9

Advertising
background image

9

Technical Data

Pressure/Temperature Rating

for standard equipment

TMA (admissible temperature) in [°C] for butt-weld ends
to DIN 3239

PMA

Form 1 – R6

Form 2 – R8

(allowable pressure)

DN [mm] (in)

DN [mm] (in)

[bar] [psi]

15 (

1

/

2

")

20*) (

3

/

4

")

25 (1")

15 (

1

/

2

")

25 (1")

105

1523

550

550

550

550

550

121

1755

540

550

550

550

550

123

1784

539

549

550

550

550

150

2175

525

535

536

550

550

180

2610

511

521

523

550

550

211

3060

500

509

511

550

550

225

3263

494

505

506

546

550

250

3625

485

497

499

538

542

275

3988

476

487

490

531

535

300

4350

467

481

484

525

528

PMX (max. differential pressure) 250 bar (3625 psi)

(inlet pressure minus outlet pressure)

Pressure/Temperature Rating

for special design (with special bolts and nuts)

TMA (admissible temperature) in [°C] for butt-weld ends
to DIN 3239

PMA

Form 1 – R6

Form 2 – R8

(allowable pressure)

DN [mm] (in)

DN [mm] (in)

[bar] [psi]

15 (

1

/

2

")

20*) (

3

/

4

")

25 (1")

15 (

1

/

2

")

25 (1")

1

67

0

972

580

580

580

580

580

1

78

1131

571

580

580

580

580

1

80

1160

569

579

580

580

580

110

1595

546

556

557

580

580

137

1987

532

541

542

580

580

144

2088

528

538

539

577

580

162

2350

519

529

530

569

580

180

2610

511

521

523

560

573

200

2900

504

513

515

554

565

225

3263

494

505

506

546

557

250

3625

485

497

499

538

550

275

3988

476

487

490

531

543

300

4350

467

481

484

525

537

*) DN 20 not covered by DIN standards.

Advertising