Wiring, Fig. 6, Fuse supply cables with t 250 ma – Flowserve NRGS 16-2 User Manual
Page 12: Tools attention wiring diagram, Open-end spanner 17 mm a. f
12
NRGS 16-2
Use multi-core flexible cable with min. conductor size 1.5 mm
2
for wiring.
1. Unscrew screws , remove housing cover Fig. 4
2. Unscrew union nuts of cable entry .
The electrode terminal can be turned through +/– 180°.
3. Loosen screw with 17 mm open-end spanner but do not remove. Fig. 5
4. Turn electrode terminal into desired direction (+/– 180°).
5. Tighten screw slightly.
6. Remove terminal strip from board.
7. Connect terminal strip according to wiring diagram, connect PE connection .
8. Plug in terminal strip.
9. Replace housing cover , fasten screws and install cable entry.
■
Fuse supply cables with T 250 mA.
Wiring
Tools
Attention
Wiring diagram
■
Screwdriver for cross head (“Phillips”) screws, size 1
■
Screwdriver for slotted screws, size 2.5; completely insulated according to VDE 0680
■
Open-end spanner 17 mm A. F.
Fig. 6
D
D
D
D
D
E
E
E
E
E
F
F
F
F
F
P
P
P
P
P
P
P
P
P
P
L
L
L
L
L
M
M
M
M
M
F
F
F
F
F
D
D
D
D
D
Mains