Gas residential heaters, Troubleshooting, Accessory – Desa CGN10R User Manual

Page 12: Specifications

Advertising
background image

12

103549

GAS RESIDENTIAL HEATERS

TROUBLESHOOTING

Note:

All Trouble Shooting items are listed

in order of operation.

WARNING: Turn off heater and let cool before servicing. Only a

qualified service person should service and repair heater.

CAUTION: Never use a wire, needle, or similar object to clean ODS/

pilot. This can damage ODS/pilot unit.

MANUAL SHUTOFF
VALVE - GA5010

Manual shutoff valve with 1/8" NPT tap.

ACCESSORY

Purchase this heater accessory from your local dealer. If they cannot
supply this accessory, either contact your nearest Parts Central (see
above) or call DESA International’s Parts Department at 1-800-972-
7879 for referral information. You can also write to the address listed
on the back page of this manual.

SPECIFICATIONS

Btu (Variable)

5,500/10,000

Type Gas

Natural Only

Ignition

Piezo

Pressure Regulator Setting

3" W.C.

Inlet Gas Pressure (inches of water)

Maximum

10.5"

Minimum

4"

Dimensions, Inches (H x W x D)

Heater

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

Weight (pounds)

Heater

14

Shipping

18

OBSERVED PROBLEM

When ignitor button is pressed and control
knob is pressed in and turned to the PILOT
position, there is no spark at ODS/pilot

POSSIBLE CAUSE

1. Ignitor electrode positioned wrong

2. Ignitor electrode broken
3. Ignitor electrode not connected to

ignitor cable

4. Ignitor cable pinched or wet

5. Piezo Ignitor nut is loose

6. Broken ignitor cable
7. Bad piezo ignitor

REMEDY

1. Replace ignitor

2. Replace ignitor
3. Reconnect ignitor cable

4. Free ignitor cable if pinched by any metal

or tubing. Keep ignitor cable dry

5. Tighten nut holding piezo ignitor to

heater cabinet. Nut is located inside
heater cabinet at top

6. Replace ignitor cable
7. Replace control valve (piezo is part of

control valve)

When ignitor button is pressed and control
knob is pressed in and turned to the PILOT
position, there is spark at ODS/pilot but no
ignition

1. Gas supply turned off or manual shutoff

valve closed

2. Control knob not in PILOT position
3. Control knob not pressed in while in

PILOT position

4. Air in gas lines when installed

5. ODS/pilot is clogged

6. Gas regulator setting is not correct

1. Turn on gas supply or open manual

shutoff valve

2. Turn control knob to PILOT position
3. Press in control knob while in PILOT

position

4. Continue holding down control knob.

Repeat igniting operation until air is
removed

5. Clean ODS/pilot (see Cleaning and

Maintenance, page 15) or replace ODS/
pilot assembly

6. Replace gas regulator

Advertising
This manual is related to the following products: