9

Eco 1030

Eco 2030

Eco 3020

Eco 4015

Mains voltage (+/-15%)

all types 230 V~ 50 / 60 Hz

Rated power*)

1080 W

1080 W

1080 W

1080 W

Charging voltage

12 V

24 V

36 V

48 V

Charging current

30 A

30 A

20 A

15 A

Nominal charging cap.

120-330 Ah

120-330 Ah

80 - 220 Ah

60 - 165 Ah

Chargeable cells

6

12

18

24

Duty cycle

all types 100 %

Charging characteristic

all types IUIoU

EMV Class

EN 61000-6-4 EN 61000-6-4 EN 61000-6-4 EN 61000-6-4
(Class A)

(Class A)

(Class A)

(Class A)

EN 61000-6-2 EN 61000-6-2 EN 61000-6-2 EN 61000-6-2
EN 61000-3-2

Degree of protection**)

all types IP 31

Operating temperature***)

all types -10°C to 50°C
all types 14°F to 122°F

Storage temperature

all types -25°C to 80°C
all types -13°F to 176°F

Weight

1950 g

1950 g

1950 g

1950 g

Dimensions (bxhxt mm)

all types 285x 70 x 142 mm

*) with the specified charging current and a charging voltage of 2.4 V / Z (e.g. 12 V corres

ponds to 14.4 V)

**)

NOTE! For indoor use only, do not expose the charger to rain or snow

Setup regulations:
-

Function-tested - 20 °C to + 50 °C

-

Component specifications:Climate class B

-

Humidity 5 % to 85 %

***) at higher temperatures a drop in performance may occur (derating)

Selectiva Eco

(continued)