Installation, Continued – Desa CF26NR User Manual

Page 13

Advertising
background image

105443-01E

For more information, visit www.desatech.com

For more information, visit www.desatech.com

13

13

INSTALLATION

Continued

INSTALLATION

Connecting To Gas Supply (Cont.)

Connecting Fireplace To Gas Supply

WARNING: Use pipe joint sealant that is resistant

to liquid petroleum (LP) gas.

O

F

F

P

IL

OT

O

N

H

I

L

O

* Purchase the optional CSA design-certified equipment shutoff
valve from your dealer. See Accessories, page 31.
** Minimum inlet pressure for purpose of input adjustment.

3" Minimum

Gas
Control

From Gas
Meter
(5" W.C.** to
10.5" W.C.
Pressure)

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

Approved Flexible
Gas Hose

Figure 19 - Gas Connection

Cap Pipe Tee

Nipple Joint

Sediment Trap

CONNECTING FIREPLACE TO GAS SUPPLY

Installation Items Needed

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not provided)

1.

Route flexible gas line (provided by installer) from equipment
shutoff valve into fireplace through side or rear access holes in
outer casing (see Figure 20).

NOTICE: Most building codes do not permit con-
cealed gas connections. A flexible gas line is pro-
vided to allow accessibility from the fireplace (see
Figure 21). The flexible gas supply line connection to
the equipment shutoff valve should be accessible.

CAUTION: Avoid damage to regulator. Hold gas

regulator with wrench when connecting it to gas
piping and/or fittings.

2.

Apply pipe joint sealant lightly to male threads of gas connec-
tor attached to flexible gas line (see Figure 21). Connect flex-
ible gas line to flexible gas line attached to gas valve of fire-
place (see Figure 21).

3.

Check all gas connections for leaks. See Checking Gas Con-
nections,
page 14.

4.

Feed flexible gas line into fireplace base area. Make sure the
entire flexible gas line is in fireplace mantel base area.

AUT

O

OF

F

ON

Figure 20 - Routing Flexible Gas Line

Equipment
Shut Off
Valve

Flexible Gas Line
from Fireplace
Gas Valve
Provided with
Fireplace

To Fireplace
Gas Valve

Figure 21 - Attaching Flexible Gas Lines Together

Gas Connector

Flexible Gas Line
from Equipment
Shutoff Valve
Provided by
Installer

Equipment Shutoff
Valve

To Gas
Supply

Outer
Casing

Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.

We recommend that you install a sediment trap in supply line as
shown in Figure 19, page 13 . Locate sediment trap where it is within
reach for cleaning. Install in piping system between fuel supply and
heater. Locate sediment trap where trapped matter is not likely to
freeze. A sediment trap traps moisture and contaminants. This keeps
them from going into fireplace controls. If sediment trap is not
installed or is installed wrong, fireplace may not run properly.

Advertising