Installation, Continued – Desa CGB3930NR User Manual

Page 10

Advertising
background image

10

104306

UVENTED NATURAL GAS LOG HEATER

CGD3924NR, CGB3924NR and CGB3930NR

Figure 10 - Attaching Flexible Gas Hose
to Heater

Figure 11 - Attaching Base Assembly to
Fireplace Floor

INSTALLATION

Continued

INSTALLING HEATER BASE
ASSEMBLY

IMPORTANT:

Make sure the heater burn-

ers are level. If heater is not level, heater will
not work properly.

WARNING: If installing in a

sunken fireplace, special care is
needed. You must raise the fire-
place floor to allow access to
heater control panel. This will in-
sure adequate air flow and guard
against sooting. Raise fireplace
floor with non-combustible mate-
rial. Make sure material is secure.

CAUTION: Do not pick up

heater base assembly by the
burner. This could damage
heater. Only handle base assem-
bly by grates.

WARNING: You must secure

this heater to fireplace floor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.

Flexible Gas Hose (if
allowed by local codes)

Fitting

Masonry Screw

Mounting
Flanges

Installation Items Needed

• hardware package (provided with heater)

• approved flexible gas hose (not provided)

(if allowed by local codes)

• sealant resistant to propane/LP gas, not

provided

• electric drill with 3/16" masonry drill bit

• two (2) 9-volt alkaline batteries (not in-

cluded)

1.

Apply pipe joint sealant lightly to male
threads of the fitting to be threaded into
gas regulator. Connect approved flex-
ible gas hose to gas regulator of heater
(see Figure 10).

2.

Locate masonary screws in hardware
package.

3.

Position heater base assembly in fire-
place.

4.

Mark screw locations through holes in
mounting flanges (see Figure 11). If in-
stalling in a brick-bottom fireplace, mark
screw locations in mortar joint of bricks.

5.

Remove heater base from fireplace.

6.

Drill holes at marked locations using
3/16" masonry drill bit.

7.

Attach base assembly to fireplace floor
using two masonry screws (in hardware
package) (see Figure 11).

8.

Connect to gas supply. See Connect-
ing To Gas Supply,
page 11.

CAUTION: Do not remove the

metal data plates attached to the
heater base assembly. The data
plates contain important warranty
information.

Advertising