Installation, Continued – Desa CGB3930NR User Manual

Page 8

Advertising
background image

8

104306

UVENTED NATURAL GAS LOG HEATER

CGD3924NR, CGB3924NR and CGB3930NR

INSTALLATION

Continued

Heat Resistant
Material

(A)

Minimum Non-Combustible
Material Clearances

If Not Using Mantel

Note:

If using a mantel, go to If Using

Mantel. If not using a mantel, follow the
information on this page.

You must have non-combustible material(s)
above the fireplace opening. Non-combus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have non-combus-
tible material behind it. Non-combustible
material must extend at least 8" up (for all
models). If non-combustible material is less
than 12", you must install the fireplace hood
accessory (24" and 30" models only). See
Figure 5 for minimum clearances.

IMPORTANT:

If you cannot meet these

minimum clearances, you must operate
heater with chimney flue damper open.

If Using Mantel

You must have non-combustible material(s)
above the fireplace opening. Non-combus-
tible materials (such as slate, marble, tile,
etc.) must be at least 1/2 inch thick. With
sheet metal, you must have non-combus-
tible material behind it. Non-combustible
material must extend at least 8 inches up (for
all models). If non-combustible material is
less than 12", you must install the fireplace
hood accessory (24" and 30" models only).
Even if non-combustible material is more
than 12", you may need the hood accessory
to deflect heat away from your mantel shelf.
See Figure 5 and Figures 6 and 7 on page 9
for minimum clearances.

IMPORTANT:

If you cannot meet these

minimum clearances, you must operate
heater with chimney flue damper open.

Non-Combustible

Requirements for

Material Distance (A)

Safe Installation

12" or more

Non-combustible material okay.

Between 8" and 12"

Install fireplace hood accessory (GA6050, GA6052,
or GA6053, see

Accessories, page 21).

Less than 8"

Non-combustible material must be extended to at
least 8". See

Between 8" and 12", above. If you

cannot extend material, you must operate heater
with flue damper open.

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

Advertising