Powermax – Hypertherm Powermax45 Service Manual User Manual
Page 128
Advertising

Component replaCement
6-24
powermax
45
Service Manual
Item
description
1
Ribbon cable (J8 connector)
2
Heat sink assembly screw
3
J10 and J12 connectors
4
J13 connector
5
J14 connector
6
J15 connector
7
J16 connector
8
J18 connector
9
J22 connector
10
Work lead connector (J21)
11
Retaining screw
12
J20 connector
Item
description
13
Resistor screws (4)
14
Pressure relief vents
15
Capacitor screws (4)
16
J19 connector
17
J17 connector
18
Input bridge diode screws (2)
19
ON/OFF switch wires
20
J1 connector
21
J2 connector
22
J3 connector
23
IGBT attachment screws (2)
24
J4, J5, and J6 connectors
older 400 V Ce power board
TP17
W
+ -
+ -
TP18
B
TP16
R
~280 VDC
~280 VDC
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
2
2
2
11
11
Advertising