Jp1: lcd panel power selection, Jp3, jp4, jp5: rs232/422/485 (com2) selection – IBASE MI953 User Manual

Page 15

Advertising
background image

INSTALLATIONS


JP1: LCD Panel Power Selection

JP1

LCD Panel Power

3.3V

5V

JP3, JP4, JP5: RS232/422/485 (COM2) Selection
COM1 is fixed for RS-232 use only.
COM2 is selectable for RS232, RS-422 and RS-485.
The following table describes the jumper settings for COM2 selection.


COM2

Function

RS-232

RS-422

RS-485


Jumper

Setting

(pin closed)

JP3:

1-2

JP4:

3-5 & 4-6

JP5:

3-5 & 4-6

JP3:

3-4

JP4:

1-3 & 2-4

JP5:

1-3 & 2-4

JP3:

5-6

JP4:

1-3 & 2-4

JP5:

1-3 & 2-4






MI953 User’s Manual

11

Advertising