4.

MAINTENANCE

NOTE!

Watch out for mains voltage when handling electric cables!

In planning product maintenance machine utilization degree and circumstances should be

considered. Careful use and preventive maintenance help to avoid unnecessary production

disturbances and breaks.

4.1 Daily maintenance

The following maintenance opeations should be carried out daily:

• Check water level and input flow, add liquid if needed.

• Check cables and connections. Tighten, if necessary and replace defect parts.

• Check that there are no leakages in the cooling water hoses.

4.2 Every sixth months

The following maintenance opeations should be carried out at least every sixth months:

• Clean off dust and dirt. Change the cooling liquid and wash up the pipes and water

reservoir with pure water.

• Check seals, cables and connections. Tighten, if necessary and replace defect parts.

4.3 Trouble shooting

See also 3.2. Overheat signal lamp.
Overheat signal lamp is lit.
The unit is overheated.

• Check water circulation.

• Check that there is enough free space behind the machine for cooling air circulation.

Error code Err 5/Err 27 on the FastMig panel

• Check the liquid hoses for damages.

• Remove any hose blockages.

• Check water circulation, add liquid if needed.

For further information and assistance, contact your nearest Kemppi service workshop.

4.4 Disposal of the machine

Do not dispose of electrical equipment with normal waste!
In observance of European Directive 2002/96/EC on waste electrical and electronic

equipment, and its implementation in accordance with national law, electrical equipment

that has reached the end of its life must be collected separately and taken to an appropriate

environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional

collection centre, per the instructions of local authorities or a Kemppi representative. By

applying this European Directive you will improve the environment and human health.