Operation 3.1 cooler operation, 2 overheat signal lamp, 3 storage – Kemppi FastCool 10 User Manual

Page 9

Advertising
background image

EN

FastMig Pulse and FastMig X
The factory default setting for FastMig Pulse is AUTO. If a cooling unit is not connected and

the operator tries to establish gas-cooled operation together with a gas-cooled gun, Err 27

is displayed. To establish gas-cooled operation, select cooler ‘OFF’. This is done in the ‘System

Config Menu’ as follows: Press the Menu button on the P 65 or X 37 power source panel. Move

the menu display arrow (via panels left-hand up-down arrow keys) to select ‘System Config

Menu’ and then press select button. Choose ‘Water Cooling:Auto’ and change via control knob

to setting ‘Water Cooling:OFF’, then press Back/Exit. Cooler will then be set to the ‘OFF’ state for

gas-cooled operation. Reset power source via on/off switch and continue welding.
When selected, the operation of the cooling unit is automatic, starting when welding

commences. When welding stops the pump will continue operation for approx. 5 min, so

reducing the gun and the cooling liquid to ambient temperature.

After completing the preparations explained above, the device is ready for welding. Before

welding, read the operating instructions.

3.

OPERATION

3.1 Cooler operation

See also 2.4.2. Main parts of cooling unit
FastMig 10 cooler operation is controlled by the microprocessor of the power supply. The

cooler pump starts to operate when the welding begins. After the welding has stopped, the

pump will operate 1 to 5 minutes longer depending on the welding time. During this time the

liquid will cool down to the ambient temperature and cools down the welding gun.
Check the tank liquid level regularly and add liquid, if necessary.
If the tanks coolant liquid level runs low, welding is stopped and an error code appears on the

FastMig panel. See trouble-shooting 4.3.

3.2 Overheat signal lamp

The overheat signal lamp is lighting when temperature control of the machine has detected

cooling water overheat. The ventilator cools down the machine and when the lamp goes out

welding can be started again.

3.3 Storage

The machine must be stored in a clean and dry room. Protect the machine from rain and keep

it away from direct sunshine in places where temperature exceeds +25° C. Check that there is

free space in front of and behind the machine for air circulation.

7

© Kemppi Oy / 1515

Advertising