EN

3.4 Temperature control PJ 33

When you turn the main switch to position 1, the circulating pump starts. If the temperature

of the coolant is higher than the temperature set at the thermoregulator, the cooling fan

also starts automatically. Otherwise, the desired cooling temperature must be set at the

thermoregulator.
Changing the set point

mute

1.

2.

1.

Unlock the set point with a long press of the up arrow key (3 s).

2.

Increase the set point value by pressing the up arrow key or decrease it by pressing the

down arrow key.

3.

When you have set the value, wait until the display returns to its initial state. The new

setting is saved automatically.

You can also use the SET button to return to initial state.

Indicator lights

mute

3.

4.

If led 3 shows white, the compressor is in operation.
If led 4 shows red, there is a fault (see the errors list).

KempCool 40

8