1.3 Properties

Description and operation principle
KempCool 40 is an efficient water cooling device. It is equipped with a fan and a radiator using

water or special non-freezing liquid as a coolant. The operating temperature range of the

device is 5…40 °C (plain water) or -20…+40 °C (non-freezing liquid) .
Excess heat is removed from the coolant with a fan. When the temperature of the coolant

rises above a set level, heat exchanger is activated and the fan starts to operate, until

the temperature gets below the set level. The activation level can be adjusted inside the

KempCool 40 cooling unit. See instructions later in this manual.
Cooling capacity
Nominal cooling capacity is 4 kW. The temperature of the coolant is always higher than the

surrounding air by 0 to 8 °C.

NOTE!

Whenever the unit is idle for longer periods of time, or if the temperature may occationally

drop below freezing point during storage or transport, empty all water flow circuits to avoid frost

damage, or make sure that the cooling brine is of non-freezing kind.

NOTE!

Do not use inflammable or explosive liquids.

NOTE!

To get special non-freezing cooling brine, please contact Kemppi Oy.

Cooling circuit
The KempCool 40 cooling device is equipped with an effective pump, which makes the

coolant continuously circulate between the heat exchanger and the welding gun. In the

welding end, the coolant absorbs heat, which is transferred to the ambient air in the heat

exchanger.
With the flow control screw you can control the flow of the cooling liquid. The level of coolant

container must be checked regularly and filled if needed.

NOTE!

Avoid running the pump dry.

NOTE!

Ensure that there is at least 40 cm free space on both sides of the machine for effective

cooling air circulation.

Cooling air
If surrounding air is heavily contaminated with particles of dust, install a filter to clean the

incoming cooling air. The filter is available as an optional accessory. The filter must be regularly

checked and replaced if needed.
Flow control
There is a flow control screw in all return lines of the cooling circuit. With this screw you can

adjust the coolant flow rate. Malfunction is indicated with a signal light in front of the cooling

unit.
Pressure alarm limit
If circulation of the coolant is for some reason weakened due to a fault somewhere in the

cooling circuit, the coolant pressure drops and the red signal light shows alarm.
With the control device located inside the cooling unit, you can set the pressure level where

the alarm is triggered.