By mounting of the mains cable take into attention the following:

The cable is entered into the machine through the inlet ring on the rear wall of the machine and

fastened with a cable clamp (05). The phase conductor of the cable is coupled to terminal L and

the neutral conductor must be coupled to terminal N. The earth protection coloured green-yellow

is coupled to connector

Sizes of the mains cable and fuse ratings for the machine at 100 % duty cycle are specified

in the table below:

Rated voltage ...................230 V 1

~

Mains voltage range .........220 V -10% … 240 V +6%
Fuse, slow-blow................10 A
Connection cable *) mm

2

..3 x 1,5 S

*) In cable of S type there is a protective grounding conductor coloured green-yellow.

3. OPERATION

3.1. PILOT LAMPS

Pilot lamp for readiness for use is connected to main switch S1 and is always illuminated,

when the machine is connected to mains supply and the main switch is in I-position.

Yellow pilot lamp H 1 of thermal protection is always illuminated when thermostat has

released due to overheating of cooling liquid. The cooling with fan is operating and when

the pilot lamp is switched off, the machine is again ready for welding.

Red pilot lamp of pressure guard is illuminated when the start pressure is under

the set minimum value.

3.2. OPERATION FUNCTIONS

MIG or TIG device starts the Procool 10 unit automatically for the welding time:

Welding time less than 15 s:

The liquid circulation ends after 15 s from welding start.

Welding time more than 15 s:

The liquid circulation is continued for 5 min starting from welding end.
If you weld again within above-mentioned 5 min, the liquid circulation is continued for 5 min

starting from next welding end.

4. OPERATION DISTURBANCES

In case of problems contact the Kemppiworks in Lahti, Finland, or your Kemppidealer.
Check service objects before sending the machine to service repair shop.

Advertising